Additel 222A Multifunction Process Calibrator

Additel 222A Multifunction Process Calibrator

  • Description
  • Features
  • Applications
  • Specifications
  • Product Video and Brochures
  • Order Info

Description

A highly integrated multifunction calibrator featuring several patented technologies, the 222A is an ultra-compact, rugged, and easy to use hand-held device for sourcing, simulating and measuring pressure, temperature, and electrical signals. Its smartphone-like menu and interface make the operation simpler and easier. The 222A is ideal for calibrating, maintaining, and troubleshooting process instrumentations. Automation and documentation capabilities make the 222A a turnkey solution.

  • Sourcing, simulating and measuring pressure, temperature and electrical signals
  • Smartphone-like menu and interface make the operation simpler and easier
  • The internal cold junction compensation sensor can be re-calibrated at ice point by users
  • Ultra-compact, 3.9” x 7.6” x 2.0”, and 1.6 lb (0.7 kg)

The 222A multifunction calibrator is a process tool for measuring, sourcing and simulating mA, mV, V, RTDs, thermocouples, ohms, frequency, pulses and pressure, captures switch values and provides 24 V loop power.

• Electrical
Resistance measurement / simulation
Voltage measurement / generation
Current measurement /generation
Frequency measurement / generation
Pulse counting/generation
24 VDC loop supply
Switch sensing

• Temperature
RTD measurement /simulation
TC measurement /simulation

• Pressure
Gauge pressure measurement
Absolute pressure measurement

Electrical Specifications

Measurement Accuracy
 RangeResolutionAccuracy
Voltage DC±75.0000 mV
±30.0000 V
0.1µV
0.1mV
0.01%RD + 3.75 μV
0.01%RD+ 1.5 mV
Current DC±30.0000 mA0.1µA0.01%RD + 1.5 μA
ResistanceTwo-wire0 to 400.000 Ω1mΩ0.02%RD + 0.02 Ω
Three-wire0 to 400.000 Ω1mΩ0.02%RD + 0.02 Ω
Four-wire0 to 400.000 Ω1mΩ0.01%RD+0.02 Ω
Two-wire0 to 4000.000 Ω10mΩ0.02%RD+0.2 Ω
Three-wire0 to 4000.000 Ω10mΩ0.02%RD+0.2 Ω
Four-wire0 to 4000.000 Ω10mΩ0.01%RD+0.2 Ω
Frequency1 to 50000.0 Hz0.1Hz0.005%RD+1 Hz
Pulse0 to 9999991N/A
Limit SwitchIf the switch has detective voltage, its range is +3V to +24V
Source Accuracy
Voltage DC-10.000 to 75.000mV 0 to 12.0000 V1μV 0.1mV0.02%RD + 4.25 μV
0.02%RD + 0.6 mV
Current DC0 to 22.000 mA1µA0.02%RD+1.1 μA
Resistance1 to 400.00 Ω 1 to 4000.0 Ω10mΩ 100mΩ0.02%RD+0.02 Ω 0.03%RD+0.4 Ω
Frequency0 to 50000.0 Hz0.1Hz0.005%RD+1 Hz
Pulse0 to 9999991N/A
DC24VN/AN/A0.5V

 

General Specifications

Environmental Specifications
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Humidity<90%, non-condensing
Safety Specifications
European ComplianceCE Mark
Mechanical Specifications
Display3.5 inch TFT color screen
Electrical Connectionφ4mm sockets and flat mini-jack thermocouple socket
RS232 Interfacestandard RS232-DB9 socket
Size3.9” x 7.6” x 2.0” (100mm x 192mm x 52mm)
Weight1.6 lb (0.7 kg)
Power SupplyPolymer Li-ion rechargeable battery, or 10V DC adaptor
BatteryRechargeable Li-ion battery (included)
Battery Life15 hours uninterrupted use Battery life will be reduced when 24V is applied
Battery Charge110V/220V external power adapter (included)
Pressure Specification
ADT 160 series Intelligent Digital Pressure Modules are available for gauge, vacuum and absolute pressure from -15 psi to 10,000 psi (-1 bar to 700 bar). Accuracy from 0.025% FS includes operation over 14°F to 122°F (-10°C to 50°C), one year stability and calibration uncertainty. For detail specification refer to pressure modules datasheet.

 

Temperature Specifications

Thermocouple Measurement and Source accuracy
Measure and Simulate Standard Temperature Range (°C)Accuracy (°C)
MeasureSource
SIEC 584-50 to 1768-50 to4001.01.1
400 to 10000.60.6
1000 to17680.70.8
RIEC 584-50 to 1768-50 to 2001.41.4
200 to 5000.60.6
500 to 17680.60.7
BIEC 5840 to 182050 to 4503.83.8
450 to 8000.90.9
800 to 18200.60.7
KIEC 584-270 to 1372-250 to -2001.01.1
-200 to -1000.40.5
-100 to 6000.30.3
600 to 13720.40.5
NIEC 584-270 to 1300-250 to -2001.51.6
-200 to -1000.50.6
-100 to 13000.40.5
EIEC 584-270 to 1000-250 to -2000.60.7
-200 to -1000.30.3
-100 to 00.20.2
0 to 7000.20.3
700 to 10000.20.4
JIEC 584-270 to 1200-210 to -1000.30.3
-100 to 12000.30.4
TIEC 584-270 to 400-250 to -2000.80.9
-200 to 00.40.4
0 to 4000.20.2
CASTM E9880 to 23150 to 10000.50.5
1000 to 18000.70.9
1800 to 23151.01.4
DASTM E9880 to 23200 to 1000.50.5
100 to 11000.40.5
1100 to 20000.60.9
2000 to 23200.91.3
GASTM E17510 to 23150 to 2002.42.4
200 to 4000.50.5
400 to 14000.40.5
1400 to 23150.71.0
LDIN43710-200 to 900-200 to -1000.20.3
-100 to 4000.20.2
400 to 9000.20.3
UDIN43710-200 to 600-200 to 00.40.4
0 to 6000.20.3
RTD Measurement and Source accuracy
Measure and Simulate Standard Temperature Range
(°C)
Accuracy (°C)
Measure
(2W/3W)
Measure
(4W)
Source
Pt10(385)IEC 751-200 to 850-100 to 2000.650.600.65
200 to 6000.820.720.82
600 to 8500.960.820.96
PT100 (385)IEC 751-200 to 850-100 to 2000.150.10.15
200 to 6000.260.160.26
600 to 8500.340.200.34
Pt100 (3916)IEC 751-200 to 850-100 to 2000.150.10.15
200 to 6000.260.160.26
600 to 8500.330.200.33
Pt200(385)IEC 751-200 to 850-100 to 2000.370.320.69
200 to 6000.510.410.92
600 to 8500.610.481.08
Pt500(385)IEC 751-200 to 850-100 to 2000.200.160.36
200 to 6000.320.220.54
600 to 8500.400.270.67
Pt1000 (385)IEC 751-200 to 850-100 to 2000.10.050.26
200 to 6000.20.100.42
600 to 8500.270.140.54
Cu100(428)GOST6651-94-50 to 150-50 to1500.120.090.12
Cu50(428)GOST6651-94-50 to 150-50 to 1500.170.130.17
Cu10(427)Minco Application Aid #18-100 to 260-100 to 2600.610.560.61
Ni120(672)Edison curve #7-100 to 260-100 to 2600.070.050.07
Ni100(618)DIN 43760-100 to 260-100 to 2600.080.060.08

 

 

For complete specs please download the product datasheet

Model NameDescription
ADT222Amain unit, include standard accessories:

  • 110V/220V external power adapter 1 pc
  • Chargeable Li-ion battery 1 pc
  • Test leads 2 sets (4 pcs)
  • short circuit cable 1 sets (2 pcs)
  • Manual
  • NIST traceable calibration certificate